更换前的准备

1.查看报错日志。

执行errpt列出报错条目

IDENTIFIER TIMESTAMP T C RESOURCE_NAME  DESCRIPTION

A39F8A49   0611123015 T S syserrlg       ERROR LOGGING BUFFER OVERFLOW

B6267342   0611123015 P H hdisk0         DISK OPERATION ERROR
A39F8A49   0611123015 T S syserrlg    
  ERROR LOGGING BUFFER OVERFLOW

从上面的输出中找出对应的IDENTIFIER,查看报错详情:errpt -aj B6267342|more

LABEL: SC_DISK_ERR2

IDENTIFIER: B6267342

 

Date/Time: Tue Oct 24 09:15:4

 

 

9 BEIST 2017

Sequence Number: 1510

Machine Id: 00C89B354C00

Node Id: DCBJLSFX04

Class: H

Type: PERM

Resource Name: hdisk0

Resource Class: disk

Resource Type: scsd

Location: U78A0.001.DNWHKW3-P2-D4

VPD:

Manufacturer................IBM

Machine Type and Model......ST3146356SS

FRU Number..................10N7204

ROS Level and ID............45363046

Serial Number...............3QN2WT58

EC Level....................D76038

Part Number.................10N7203

Device Specific.(Z0)........000005329F001002

Device Specific.(Z1)........0120E60F

Device Specific.(Z2)........0021

Device Specific.(Z3)........09347

Device Specific.(Z4)........

Device Specific.(Z5)........22

Device Specific.(Z6)........D76038

 

Description

DISK OPERATION ERROR

 

Probable Causes

DASD DEVICE

 

Failure Causes

DISK DRIVE

DISK DRIVE ELECTRONICS

 

    Recommended Actions

    PERFORM PROBLEM DETERMINATION PROCEDURES

 

Detail Data

PATH ID

0

SENSE DATA

0A00 2A00 0751 0B30 0000 4804 0000 0000 0000 0000 0000 0000 0102 0000 7000 0100

0000 0018 0000 0000 5D00 0800 0000 0000 015D 0008 FFFF FFFF FFFF 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 18C2 000B D900 0000 0000 0000 0000 0000 0000 0000 0083 0000

0000 0010 000D

 

Diagnostic Analysis

Diagnostic Log sequence number:    2049

Resource tested:    hdisk0

Resource Description:    SAS Disk Drive

Location:        U78A0.001.DNWHKW3-P2-D4

SRN:            2556-130

Description:        Error log analysis indicates problem reported by disk

drive's self monitoring function.

Possible FRUs:

hdisk0 FRU: 10N7204 U78A0.001.DNWHKW3-P2-D4

SAS Disk Drive

 

2.查看HDISK0S/NP/N号等,在换盘的时候做对照  lscfg –vl hdisk0  

hdisk0U78A0.001.DNWHKW3-P2-D4 Other SCSI Disk Drive

 

Manufacturer................MAXTOR

Machine Type and Model......ATLAS10K5_73SCA

ROS Level and ID............4A4E5A48

Serial Number...............D210K4XK

Device Specific.(Z0)........000003025B00013E

Device Specific.(Z1)........

注意locationU78A0.001.DNWHKW3-P2-D4要与机器对应无误

 

3.确认原有的状态

显示一个卷组中的所有物理卷信息,名称,状态,和分区情况:lsvg -p rootvg

rootvg:

PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION

hdisk0 missing 548 503 109..100..75..109..110

hdisk1 active 548 503 109..100..75..109..110

确认镜像状态lsvg -l rootvg

rootvg:

LV NAME TYPE LPs PPs PVs LV STATE MOUNT POINT

hd5 boot 1 2 2 closed/stale N/A

hd6 paging 8 16 2 open/syncd N/A

hd8 jfs2log 1 2 2 open/stale N/A

hd4 jfs2 2 4 2 open/stale /

hd2 jfs2 19 38 2 open/stale /usr

hd9var jfs2 5 10 2 open/stale /var

hd3 jfs2 1 2 2 open/stale /tmp

hd1 jfs2 1 2 2 open/stale /home

hd10opt jfs2 4 8 2 open/stale /opt

hd11admin jfs2 1 2 2 open/stale /admin

livedump jfs2 2 4 2 open/stale /var/adm/ras/livedump

注意LPs和PPs一定要为1:2

查看rootvg卷组的详细信息及状态:lsvg rootvg

VOLUME GROUP: rootvg VG IDENTIFIER: 00c57e5f00004c000000015f342b9397

VG STATE: active PP SIZE: 128 megabyte(s)

VG PERMISSION: read/write TOTAL PPs: 1096 (140288 megabytes)

MAX LVs: 256 FREE PPs: 1006 (128768 megabytes)

LVs: 11 USED PPs: 90 (11520 megabytes)

OPEN LVs: 10 QUORUM: 1 (Disabled)

TOTAL PVs: 2 VG DESCRIPTORS: 3

STALE PVs: 1 STALE PPs: 31

ACTIVE PVs: 1 AUTO ON: yes

MAX PPs per VG: 32512

MAX PPs per PV: 1016 MAX PVs: 32

LTG size (Dynamic): 128 kilobyte(s) AUTO SYNC: no

HOT SPARE: no BB POLICY: relocatable

PV RESTRICTION: none INFINITE RETRY: no

注意STALE PVs/PPs数量

4.迁移dump设备

因为原先系统在做镜像时,dump设备不会被镜像,所以现在要确定好dump设备的位置

如果在坏盘hdisk0上,此时应当迁移至hdisk1上。反之,如果在好盘hdisk1上,则无需此迁移步骤。

确认dump设备位置:lspv -l hdisk0,lspv -l hdisk1

hdisk0:
LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT
hd6                   2       4       00..02..00..00..00    N/A
hd8                   1      
2       00..00..01..00..00    N/A
hd5                   1      
2       01..00..00..00..00    N/A
hd9var                4      
8       00..00..04..00..00    /var
hd3                   16      
32      00..00..16..00..00    /tmp
hd4                   8      
16      00..00..08..00..00    /
hd2                   16      
32     00..00..16..00..00    /usr
hd1                   4      
8      00..00..04..00..00    /home
hd10opt               11      
22      00..00..11..00..00    /opt
livedump              1      
2       00..01..00..00..00    /var/adm/ras/livedump
lg_dumplv             4      
4       00..04..00..00..00    N/A
hd11admin             1      
2       00..00..01..00..00    /admin

hdisk0上,须做迁移:migratepv -l lg_dumplv hdisk0 hdisk1

确认lg_dumplv已经迁移到hdisk1上:lspv -l hdisk1

 

HDISK0ROOTVG的镜像中移除unmirrorvg rootvg hdisk0  

0516-1246 rmlvcopy: If hd5 is the boot logical volume, please run 'chpv -c <diskname>'

as root user to clear the boot record and avoid a potential boot

off an old boot image that may reside on the disk from which this

logical volume is moved/removed.

0516-1804 chvg: The quorum change takes effect immediately.

0516-1144 unmirrorvg: rootvg successfully unmirrored, user should perform

bosboot of system to reinitialize boot records. Then, user must modify

bootlist to just include: hdisk1.

 

查看物理卷状态  lspv  rootvg

hdisk0 00c57e5fa8a95af5 rootvg active

hdisk1          00c3f435d0f4916c                    rootvg          active

查看pv上的逻辑卷状态(LPsPPs的比例为11lspv -l hdisk1hdisk1:

LV NAME LPs PPs DISTRIBUTION MOUNT POINT

LV NAME               LPs     PPs     DISTRIBUTION          MOUNT POINT

hd6                   2       2       00..02..00..00..00    N/A
hd8                   1       1       00..00..01..00..00    N/A
hd5                   1       1       01..00..00..00..00    N/A
hd9var                4       4       00..00..04..00..00    /var
hd3                   16      16      00..00..16..00..00    /tmp
hd4                   8       8       00..00..08..00..00    /
hd2                   16      16      00..00..16..00..00    /usr
hd1                   4       4       00..00..04..00..00    /home
hd10opt               11      11      00..00..11..00..00    /opt
livedump              1       1       00..01..00..00..00    /var/adm/ras/livedump
lg_dumplv             4       4       00..04..00..00..00    N/A
hd11admin             1       1       00..00..01..00..00    /admin

这时HDISK0不再和HDISK1MIRROR  ,把hdisk0rootvg中去除  reducevg rootvg hdisk0  

 

 

更换新硬盘

 

AIX上通过diag判定DISK位置

#diag 执行命令回车

选择黑色部分

用PgDn键翻页找到Hot plug Task回车

选择黑色部分,回车

继续选择黑色部分

选择想判定位置的目标DISK,比如:hdisk0

回车,这个时候去观察硬盘,你会发现硬盘的指示灯会显示"红色",这个硬盘就是你需要判定的目标盘。

如果想把这个有故障的硬盘从SCSI剔除,F3返回上一级菜单选择"Replace/Remove a Device Attached to an SCSI Hot Swap Enclosure Device"

光标移到hdisk0处,回车

然后拔掉故障磁盘,插上新的磁盘,执行cfgmgr –v,重新识别出新插的磁盘。

消除系统警告灯

选择黑色部分,回车

 

 

 

用Enter键选择黑色部分,在按F7或者Esc+7键commit

(这里再补充另一种删除硬盘的方法:reducevg后执行rmdev -dl hdisk0 但非常不推荐使用。具体步骤请自行百度)

 

重做镜像

确认新盘hdisk0是否有PVIDlspv  rootvg

hdisk000c2f65fa4a27df5 none none

hdisk1          00c3f435d0f4916c                    rootvg          active

上面标红的即是。

如果没有,需要手动添加:chdev -l hdisk0 -a pv=yes

 

HDISK0出现后, HDISK0加到ROOTVG  

#extendvg rootvg hdisk0 

  

MIRROR  mirrorvg –S rootvg (也可执行mirrorvg –c 2 rootvg 等待时间较长) 

0516-1804 chvg: The quorum change takes effect immediately.

0516-1126 mirrorvg: rootvg successfully mirrored, user should perform

bosboot of system to initialize boot records. Then, user must modify

bootlist to include: hdisk1 hdisk0.

 

查看PV  lspv  

Hdisk0          00x9k241k2l3811n                    rootvg          active

hdisk1          00c3f435d0f4916c                    rootvg          active

 

HDISK0上创建boot image  

bosboot –ad hdisk0  

bosboot: Boot image is 51228 512 byte blocks

先确认当前启动顺序bootlist –m normal -o

改变启动设备的顺序  bootlist –m normal hdisk0 hdisk1 cd0 

确认修改后的启动顺序bootlist –m normal -o

后续操作:在HMC上关闭事件,系统中执行errclear 0清空相关报错。

 

 

一些补充:

若该机器上有多个lpar,哪个报出来的就在哪个上操作,另一个lpar上不用动。

换硬盘过程中不需要重启。

reducevg后可能产生的其他报错http://blog.sina.com.cn/s/blog_149d7c9f30102vsae.html

若遇到hmc终端打不开(java版本问题),可尝试使用vtmenu

 

 

转载于:https://www.cnblogs.com/jonathanyue/p/9301262.html

你可能感兴趣的文章
Cesium几个案例介绍
查看>>
浏览器的F12相关知识点
查看>>
js中arguments的用法
查看>>
65条最常用正则表达式,你要的都在这里了
查看>>
YUM 安装与配置(转载)
查看>>
2018寒假编程总结1
查看>>
could not stop cortex-m device
查看>>
[转载]如何有效提升项目把控力
查看>>
每日分享
查看>>
白话排序算法--快速排序
查看>>
Apache 配置代理服务
查看>>
Oracle 判断 并 手动收集 统计信息 脚本
查看>>
收缩临时表空间
查看>>
javascript面向对象一:函数
查看>>
Firebird 数据库使用经验总结
查看>>
martini-能量最小化参数(mdp文件)
查看>>
.net mvc 几种跨域获取数据方案
查看>>
[bzoj2668] [洛谷P3159] [cqoi2012] 交换棋子
查看>>
互联网创业的准备——后勤:电脑、邮箱、会议
查看>>
[原创]基于Zynq Linux环境搭建(三)
查看>>